Page not found

Search results

  1. 2021-2025 Amended Capital Improvement Plan

    Finance | Page

    Maintenance Five Year Plan Summary 24‐25 City Hall RTU #3 26 City Hall RTU #1 27 ... 106 CP 2019‐2, GR/Cohasset Connection Trail Phase 2 107 Year Project Starts: 2024 ... 1 City Council Resolution Adopting the 2021 ‐ 2025 2‐3 City of Grand Rapids Amended Capital Improvement Plan Five Year ...

  2. Community Development Fee Schedule

    Community Development | Page

    each additional $1,000.00 or fraction thereof, to and including $25,000.00 (3-27-06) $25,001.00 to ... Annual building Permit (as per MN Rule 1300.0120, Subparts 2 and 3) $505.00* Plan Review Fee (3-27-06 ... Door (12-17-12) $40.00 $1.00 $41.00 Siding Replacement (3-27-06) $60.00 $1.00 $61.00 All Regulated ...

  3. Fasteners

    Community Development | Page

    24” o.c. Built-up girders and beams, 2-inch lumber layers 10d Nail each layer as follows: 32” o.c. at ... diameter, 1 3/8” long, 7/32” head. Screws: Screws shall be Type S or W and penetrate into wood framing ... 1 5/8” long, 9/32” head. Screws: Screws shall be Type S or W and penetrate into wood framing a minimum of ...

  4. Structural Engineers Reports

    Administration | Page

    6 years until 2003 when the 2000 international building code (IBC) was adopted in Minnesota. Under the ... be corrected immediately and that the building has stood basically undamaged for nearly 55 years. 3. ... laws of the State of Minnesota. Jon E. Aamodt, P.E. Date MN Reg. No. 24838 11-06-17 2.46 = stress ratio ...

  5. City Council Regular Meeting

    City Council | Calendar Event | 07/27/15 04:00pm

    Contracts 40 1, 245 33 32 System Maintenance Contracts 35,964 33,252 35,420 35, 151 48, 231 24,049 12, 000 ... Cemetery, Storm Water and Engineering /Airport. August 24 Continued Department presentation of 2016 proposed ... FIRE DEPARTMENT ACTUAL 2011-2014 EXPENDITURES, 2015 BUDGET, YEAR TO DATE, PROPOSED 2016 BUDGET 7/ 23/ ...

  6. Gypsum Wallboard

    Community Development | Page

    spaced not more than 24 inches on center. Exterior or bearing walls must be 2 X 4 minimum and spaced not ... more than 24 inches on center (R602.5). Other framing supporting gypsum board, such as for soffits or ... 7/32” head. Screws: Screws shall be Type S or W and penetrate into wood framing a minimum of 5/8 inch. ...

  7. Footings, Foundations & Slabs

    Community Development | Page

    over light frame or 8-inch hollow concrete masonry 1-story 12 12 12 2-story 21 16 12 3-story 32 24 16- ... @ 48” #5 @ 48” #6 @ 48” #6 @ 40” #6 @ 24” #4 @ 56” #4 @ 56” #5 @ 56” #6 @ 56” #6 @ 32” #4 @ 72” #4 @ 72” ... @ 72” #6 @ 72” #6 @ 64” #4 @ 48” #4 @ 48” #5 @ 48” #6 @ 48” #6 @ 32” #6 @ 24” #6 @ 16” #4 @ 56” #4 @ 56” ...

  8. City Council Regular Meeting

    City Council | Calendar Event | 09/10/12 04:00pm

    Stay Space Jane Barthell for the projec[. Update 30-year-old HVAC systems Cindy Brummer Safer ... for each of the two subsequent years. Tautges Redpath, the City's auditors at that time, reduced ... $33,500 for the last three years, and 13,500 for the Airport audit, Single audit, and out of pocket costs, ...

  9. 2023 Ancillary Services and Fees

    Public Utilities | Page

    24 hour notice No Charge (during regular working hours) Electric Temporary Use Meter $485.00 Minimum ... disconnects > 1 per year $100.00 Seasonal reconnects > 1 per year $100.00 Seasonal (one disconnect & ... reconnect per year) No Charge Monthly service charge continues Emergencies No Charge Plumbing Repairs with ...

  10. MPCA MS4 Permit Public Notice Copy

    Engineering / Public Works | Page

    https://www.pca.state.mn.us wq-strm4-49a • 9/ /20 Page 24 of 32 MCM 6: Pollution prevention/Good housekeeping for municipal ... formats https://www.pca.state.mn.us wq-strm4-49a • 9/ /20 Page 1 of 32 MS4 Part 2 Permit Application ... wq-strm4-49a • 9/ /20 Page 2 of 32 I certify under penalty of law that this document and all attachments were ...

Pages