Page not found

Search results

  1. Water Quality Reports

    Public Utilities | Page

    2018 Water Quality Report: 2017 Water Quality Report: 2016 Water Quality Report: 2015 Water Quality ... Lead (11/14/18) 0 ppb 90% of homes less than 15 ppb 4.4 ppb 0 out of 20 NO Corrosion of household ... plumbing. Copper (11/14/18) 0 ppm 90% of homes less than 1.3 ppm 1.04 ppm 1 out of 20 NO Corrosion of ...

  2. Roofing

    Community Development | Page

    The bottom layer must be at least 18 inches wide and the top layer at least 36 inches wide.  For ... 2 3 ½ 4 No. 3 3 3 ½ 18 No. 1 4 ¼ 5 ½ No. 2 4 4 ½ No. 3 3 ½ 4 24 No. 1 5 ¾ 7 ½ No. 2 5 ½ 6 ½ No. 3 5 5 ½- 7- ... starter course at the eaves must be doubled and the bottom layer may be 15-inch, 18-inch, or 24-inch wood ...

  3. Basic Wood Framing

    Community Development | Page

    2 2-2×4 2-7 1 2-3 1 2-0 1 CRAWL SPACES Treated joists if less than 18” to ground Treated plate Treated ... 1 1-8 1 1-5 2 2-2×6 2-11 2 2-7 2 2-3 2 2-2×8 3-9 2 3-3 2 2-11 3 2-2×10 4-7 3 4-0 3 3-6 3 2-2×12 5-4 ... NO STORAGE IN ATTIC 2 x 4 2 x 6 2 x 8 2 x 10 12” o.c. Hem Fir 11-7 18-2 24-0 26+ SPF 11-10 18-8 24-7 ...

  4. 2023 Rural Electric Service Rate Schedule

    Public Utilities | Page

    Effective 01/01/2023 Last Revised: Adopted 12/15/2021 Effective 04/01/2022 Adopted 12/18/2019 Effective ... 05/01/2021 Adopted 12/18/2019 Effective 09/01/2020 ...

  5. City Council Regular Meeting

    City Council | Calendar Event | 09/24/12 04:00pm

    Spare Key Appreciation Day in Grand Rapids Attachments: Spare Kev Proclamation 5:07 MEETING PROTOCOL ... available in the wall file by the Council entrance. 5:08 PUBLIC FORUM p.m. 5:13 COUNCIL REPORTS p.m. 5:18 ... APPROVAL OF MINUTES p.m. 5:18 CONSENT AGENDA p.m. Any item on the consent agenda shall be removed for ...

  6. Itasca Calvary Cemetery

    Community | Page

    3534313029 3839 3637404142 4746 4948454443 9 8 23 22 21 20 19 18 17 9 10 11 12 1314 15 16 ... 5 64321 8 791011 16151413 12 17 192021 2524 2728 30 23 22 18 26 31 29 3839 37404142 494746 48454443 505253 ...

  7. Decks

    Community Development | Page

    Area of Deck Supported in Sq Ft Footing Diameter Required in Inches 14 8 43 14 87 20 18 9 49 15 96 21 ... 22 10 56 16 106 22 26 11 63 17 116 23 32 12 71 18 126 24 37 13 79 19 137 25 Required footing sizes ... SPAN (ft) 6’ and less 6’1” to 8’ 8’1” to10’ 10’1” to 12’ 12’1” to 14’ 14’1” to 16’ 16’1” to 18 ...

  8. A look inside the Grand Rapids Fire Department

    Fire | News/Press Release | Dec 15, 2021

    group of volunteers. In 2018, firefighters responded to 149 calls which required the entire department. ... That entire department response is decreased from 176 responses in 2017. 2018 brought changes in ...

  9. Planning Commission Regular Meeting

    Planning Commission | Page | 04/18/13 04:00pm

    Meeting with Agenda and Minutes Thursday, April 18, 2013- 4:00pm Agenda Image Slideshow Display ...

  10. Economic Development Authority Regular Meeting

    Economic Development Authority | Page | 10/18/16 04:00pm

    Meeting with Agenda and Minutes Tuesday, October 18, 2016- 4:00pm Agenda Image Slideshow Display ...

Pages