Page not found

Search results

  1. Roofing

    Community Development | Page

    shingles must be:  galvanized steel  stainless steel  Aluminum  copper roofing nails  minimum 12 gauge ... of two units vertical in 12 units horizontal (2:12) or greater. For roof slopes from 2:12 to 4:12 ... ASTM D 6757. For slopes of 4:12 and greater, underlayment must be applied shingle fashion. Laps must be ...

  2. Community Development Fee Schedule

    Community Development | Page

    negotiate this component of the building permit fee with the project owner/developer. (revised 4-12 ... Permit Fee Plan Check Fee State Surcharge Fee Total Fee Re-roofing (12-17-12) $60.00 $1.00 $61.00 Garage ... Door (12-17-12) $40.00 $1.00 $41.00 Siding Replacement (3-27-06) $60.00 $1.00 $61.00 All Regulated ...

  3. Special Assessments

    Engineering / Public Works | Page

    Special Assessments Sort A to Z 12-8-08_spec_assessment_policy-final_1.pdf CITY OF GRAND RAPIDS SPECIAL ... standard term of assessment for public improvements shall be ten (10) or fifteen (15) years. The Council ... or septic system within the past twenty years, and the well and/or septic system is still compliant, ...

  4. City Council Worksession

    City Council | Calendar Event | 09/12/22 04:00pm

    Meeting with Agenda and Minutes Monday, September 12, 2022- 4:00pm Agenda Minutes Video Image ... kgibeau@ci.grand-rapids.mn.us 12a55a04-80f6-4f1d-93c9-3d613ff360ef Sort A to Z Agenda (HTML) Agenda Packet (HTML) ...

  5. Building Plans

    Community Development | Page

    REAR LEFT SIDE SCALE ¼ INCH = 1 FOOT 12’ 3 ½ Inch #4 Rebar at 30” O.C. each ½ Inch OSB Sheathing ... Double Top Plate Manufactured Wood Trusses 24” o.c. 10 Inch by ½ Inch Anchor Bolts 6 Ft o.c., 12 inches ... from end of each piece 240# Asphalt Shingles over Type I Felt. Garage Footer 12 Inches Deep by 12 ...

  6. Electric Distribution

    Public Utilities | Page

    September 1, 2015. In addition, beginning in 2019, the generation capacity charge for each year is based on ... previous year’s average annual billed demand, excluding any existing renewable generation capacity prior to ... the previous year generation capacity charge adjusted as determined by the power supply formula rate ...

  7. Grand Rapids Area Cable Commission

    Grand Rapids Area Cable Commission | Page

    The Greater Grand Rapids Area Cable Commission meets quarterly at 12:00 PM  in the ICTV Studio, ... @ 12pm in the ICTV Studio Sort A to Z ...

  8. Site Plans

    Community Development | Page

    Exst. 12X12 Shed Proposed New 12X24 Ft Garage Driveway Scale 1” = 10’ Proposed New Garage Existing ...

  9. Fasteners

    Community Development | Page

    12 gauge shank with a minimum 3/8” diameter head and of a length to penetrate through the roofing ... a minimum of 5/8 inch. 1/2 “ Nails: 13 gage, 1 3/8” long, 19/64” head; 0.098 diameter, 1 ¼” long, annular- ... 6 12 19/32 – 1 8d common nail 6 12 1 1/8 – 1 ¼ 10d common nail or 8d deformed nail 6 12 a. All nails ...

  10. Concrete Slabs

    Community Development | Page

    footings must extend 12 inches below undisturbed ground  Detached garages, sheds and other detached ... a maximum of 6 feet apart and within 12 inches of each end. Bolts must be at least ½” diameter and extend at ... aggregate ¾ inch and larger 4 8 10 12 5 10 13 15 6 12 15 18 HOT AND COLD WEATHER ISSUES Hot Weather Hot ...

Pages